Breaking through the theoretical framework and bottleneck that traditional high-temperature corrosion inhibitors can only use phosphorus-based systems, it provides good corrosion inhibition under vacuum conditions at 220-360°C, and avoids fouling, blockage and unplanned shutdowns of downstream units such as hydrotreating caused by phosphorus-containing high-temperature inhibitors.
| Project | Technical Indicators | Testing Standards/Methods |
|---|---|---|
| Appearance | homogeneous liquid | Visual inspection |
| Solubility | Miscible with aromatic hydrocarbons in any ratio | Visual inspection |
| Density (20°C), g/cm³ | 0.95-1.00 | GB/T 2540 |
| Freezing point, °C | ≤-10 | GB/T 510 |
| Closed cup flash point, °C | ≥61 | GB/T 261 |
| Phosphorus content, % | ≤0.01 | SH/T 0296-1992 |
| Chloride ion content, % | ≤0.01 | ASTM D7536 |
| Corrosion inhibition rate, % | ≥90 | Q/WRUN002-2019 |
| Acid value, mgKOH/g | ≤7 | GB/T 7304 |
| Nitrogen content, % | ≥0.37 | - |
When the feedstock acid value is ≥0.5 mgKOH/g and the temperature exceeds 200°C, it is strongly recommended to choose BXH-103/RUN-129 instead of ordinary phosphorus-containing high-temperature inhibitors, addressing both high-temperature corrosion and the impact of phosphorus on oil quality.
Residue oil system at the bottom of the pressure reduction tower, 250–320°C high temperature oil and gas corrosion environment
High temperature and high pressure hydrogen environment, NH₄HS·HCl compound corrosion conditions
Delayed coking high-temperature oil and gas pipelines containing H₂S·Organic acid corrosion
Park refinery with zero phosphorus emission requirements, replacing phosphorus-containing high-temperature corrosion inhibitors
High-acid crude (TAN>1.0 mgKOH/g) causes severe naphthenic acid corrosion above 220°C; BXH-103 can be applied by online injection for protection
Vacuum tower high-temp packing is the most severe corrosion zone; inject via 1st/2nd mid-pump-around or atmospheric bottoms feed pump.
FCC slurry recycle line (250–350°C): catalyst particle erosion + naphthenic acid corrosion; BXH-103 provides dual high-temp and erosion protection
Replaces phosphorus-containing high-temp inhibitors to meet oil-phase phosphorus-free requirements while keeping inhibition efficiency and comparable overall cost
BXH-103 / RUN-129 solve the two major problems of high temperature corrosion and environmental protection standards for you at the same time